If the actuator does not perform home return, confirm that the *pause signal is ON, the motor-drive power supply

is receiving power, and no error messages are displayed, among others.

(10) Set the target position, speed, acceleration/deceleration, positioning band and other data in the position table.

For details on how to set data in the position table, refer to the operation manual for the teaching pendant or PC

software, whichever is applicable.

Now, you can operate the actuator automatically via control from the PLC.

Caution: Issue a command from the PLC after confirming that the position complete output (PEND) is ON.