7.11 Incremental Moves

Example of use in operation) Move the actuator from the home to the 30-mm position (position No. 1) set in the

absolute mode, and then move the actuator further through continuous incremental

moves at a 10-mm pitch until the final position of 200 mm is reached. (Pitch feed is

specified by position No. 2.)

ERC2 controller

P

L

C

[1]

[6]

[10] [8] [5] [3]

PIO

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

*Pause

Position complete

Home return completion

Zone

*Alarm

Category

Input

Output

[9] [7] [4] [2]

Reference flow

Select/enter command position 1.

Start input ON

Movement to position 1 starts.

Position complete output OFF

Start input OFF

Position complete output ON

Select/enter command position 2.

Start input ON

Position complete output OFF

Start input OFF

Movement to the +10 mm position completes.

Position complete output ON

Movement to position 1 completes.

Movement to +10 mm from the current position starts.