IAI America ERC2 User Manual

Page 162

Advertising
background image



9. T

roubleshooting

139

Code

Error name

Cause/Action

F5 Verification error of data

written to nonvolatile

memory

When data was written to the nonvolatile memory, the written data is read and

compared (verified) against the original data.

This alarm indicates that the read data does not mach the original data written.

Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(As a rough guideline, the nominal service life of the nonvolatile

memory is 100,000 rewrites.)

Action: If the alarm persists after reconnecting the power, contact IAI.

F6 Timeout writing to

nonvolatile memory

This alarm indicates that a response was not received within the specified time

after writing the nonvolatile memory.

Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(As a rough guideline, the nominal service life of the nonvolatile

memory is 100,000 rewrites.)

Action: If the alarm persists after reconnecting the power, contact IAI.

F8 Damaged nonvolatile

memory

Abnormal data was detected in the nonvolatile memory check upon start.

Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(As a rough guideline, the nominal service life of the nonvolatile

memory is 100,000 rewrites.)

Action: If the alarm persists after reconnecting the power, contact IAI.

FA CPU error

The CPU is not operating normally.

Cause: [1] Faulty CPU

[2] Malfunction due to noise

Action: If the alarm persists after reconnecting the power, contact IAI.