Parameter settings, 1 parameter table – IAI America ERC2 User Manual

Page 144

Advertising
background image

0

8. Parameter Settings

121

8. Parameter Settings

8.1 Parameter Table

Parameters are classified into four types according to their content.

Category:

a: Parameter relating to the actuator stroke range

b: Parameter relating to the actuator operating characteristics

c: Parameter relating to the external interface

d: Servo gain adjustment

No.

Category

Name

Unit

Default factory setting

1

a

Zone boundary 1+

mm

Effective actuator length

2

a

Zone boundary 1–

mm

Effective actuator length

3

a

Soft limit+

mm

Effective actuator length

4

a

Soft limit–

mm

Effective actuator length

5

a

Home return direction

(0: [Reverse]/1: [Forward])

-

(In accordance with the specification at the time

of order)

6

b

Push & hold stop judgment period

msec

255

7

d

Servo gain number

-

Set individually in accordance with the actuator

characteristics.

8

b

Default speed

mm/sec Set individually in accordance with the actuator

characteristics.

9

b

Default acceleration/deceleration

G

Set individually in accordance with the actuator

characteristics.

10

b

Default positioning band (in-position)

mm

0.10

12

b

Current-limiting value at standstill during

positioning

%

Set individually in accordance with the actuator

characteristics.

13

b

Current-limiting value during home return

%

Set individually in accordance with the actuator

characteristics.

15

c

Pause input disable selection

(0: [Enable]/1: [Disable])

-

0 [Enable]

16

c

SIO communication speed

bps

38400

17

c

Minimum delay time for slave transmitter

activation

msec

5

22

a

Home return offset

mm

Set individually in accordance with the actuator

characteristics.

25

c

PIO pattern selection

-

0 (8 points)

27

c

Movement command type (0: [Level]/1: [Edge])

-

0 [Level]

28

b

Default direction of excited-phase signal

detection (0: [Reverse]/1: [Forward])

-

Set individually in accordance with the actuator

characteristics.

29

b

Excited-phase signal detection time

msec

Set individually in accordance with the actuator

characteristics.

31

d

Speed loop proportional gain

-

Set individually in accordance with the actuator

characteristics.

32

d

Speed loop integral gain

-

Set individually in accordance with the actuator

characteristics.

33

d

Torque filter time constant

-

Set individually in accordance with the actuator

characteristics.

34

b

Push speed

mm/sec

Set individually in accordance with the actuator

characteristics.

35

b

Safety speed

mm/sec

100

36

b

Automatic servo-off delay time 1

sec

0

37

b

Automatic servo-off delay time 2

sec

0

38

b

Automatic servo-off delay time 3

sec

0

39

c

Output mode of position complete signal

(0: [PEND]/1: [INP])

-

0 [PEND]

40

c

Home-return input disable selection

(0: [Enable]/1: [Disable])

-

0 [Enable]

45

c

Silent interval multiplication factor

times

0 (Multiplication factor is not applied)

46

b

Speed override

%

100

53

b

Default standstill mode

-

0 [Complete stop]

(Note) The numbers are displayed in the PC software, but not on the teaching pendant.

Skipped numbers are not used and therefore omitted.