7.7 Speed Change during Movement

Example of use in operation) The actuator speed is reduced at a certain point during movement.

The position 150 mm from the home is set as position 1, and the position 200 mm

from the home is set as position 2. The actuator is initially located between the home

and position 1. The actuator is moved to position 2 being the target position, at a

travel speed of 200 mm/sec to position 1 and that of 100 mm/sec from position 1 to

position 2.

Method) In this example, the actuator is caused to move to position 1 and to position 2

successively. Before the actuator is stopped at position 1, command position 2 must

be selected/entered and the start signal must be input. To do this, set a wide

positioning band at position 1 and cause the start signal for movement to position 2 to

be input immediately after the completion signal for movement to position 1 is output.

(Command position 2 should be entered while the actuator is moving to position 1.)

ERC2 controller

[9] [7] [4] [2]

[1]

[5]

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

*Pause

Position complete

Home return completion

Zone

*Alarm

Category

Input

Output

[10] [8] [6] [3]

P

L

C

PIO

Reference flow
Select/enter command position 1.

Start input ON

Movement to position 1 starts at 200 mm/sec.

Position complete output OFF

Start input OFF

Select/enter command position 2.

Start input ON

Position complete output OFF

Start input OFF

Movement to position 2 completes.

Position complete output turns

ON 10 mm before position 1.

Movement to position 2 starts at 100 mm/sec.

Position complete output turns

ON 0.1 mm before position 2.

[1]

[2]

[3]

[4]

[5]

[6]

[7]

[8]

[9]

[10]