IAI America XSEL-KET User Manual

Page 142

Advertising
background image

123

Part 4 Commands

INTELLIGENT ACTUATOR



OUTB (Write output, flag as BCD)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

OUTB

Output, flag BCD digits

CC

[Function]

Write the value in variable 99 to the output ports or flags from the one specified in operand 1
for the number of digits specified in operand 2 as a BCD.


85

Variable 99





307 306 305 304

303

302

301

300

Output port number

ON OFF OFF OFF

OFF

ON

OFF

ON



(Note 1)

A maximum of eight digits (32 bits) can be output.

(Note 2)

The number of output ports and flags that can be used is 4 x n (digits).

(Note 3)

The read data format can be changed using a FMIO command (refer to the section on FMIO
command). (This function is available only in main application version 0.56 or later.)


[Example 1]

OUTB

300

2

Write the value in variable 99 to the output ports from
300 for two digits (until output port 307) as a BCD.

[Example 2]

LET

1

300

Assign 300 to variable 1.

LET

2

2

Assign 2 to variable 2.

OUTB

*1

*2

Write the value in variable 99 to the output ports from
the content of variable 1 (output port 300) for the
content of variable 2 (two digits) (until output port 307)
as a BCD.