Other Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

21 Manual

operation

type

0

0 ~ 5

0: Always enable edit and SIO/PIO start (Initial condition

after connection = With safety speed)

1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial condition

after connection = Without safety speed
(cancellation)) (PC software version 1.1.0.7 or later
and TP application version 1.06 or later)

* Referenced by the PC/TP.

22 Control use region

0

0 ~ 99

0: J, 1: E, 2: EU

23 PSIZ

command

function type

0

0 ~ 5

0: Maximum number of point data areas
1: Number of point data used

24 Local

variable

number for storing
SEL communication
command return
code

99

1 ~ 99

1001 ~ 1099

(Main application version 0.20 or later)

25~

29

(For extension)

0

30 Option Password 00

0H

0H ~

FFFFFFFFH

HOME command option (Change prohibited)
(Main application version 0.50 or later)

31 Option Password 01

0H

0H ~

FFFFFFFFH

Reserved (Change prohibited)

32 Option Password 02

0H

0H ~

FFFFFFFFH

Reserved (Change prohibited)

33~

35

(For extension)

0H

0H ~

FFFFFFFFH

36 PC/TP data protect

setting (Program)

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Protect type (0: Read/write, 1: Read only,
2: No read/write)

Bits 4 to 7:

Protect release method (0: Special
operation)

Bits 8 to 11:

Protect range maximum number (1’s
place, BCD)

Bits 12 to 15: Protect range maximum number (10’s

place, BCD)

Bits 16 to 19: Protect range minimum number (1’s

place, BCD)

Bits 20 to 23: Protect range minimum number (10’s

place, BCD)

* Referenced by the PC/TP (PC software version

2.0.0.42 or later and TP application version 1.09 or
later)