I/o parameters – IAI America XSEL-KET User Manual

Page 355

Advertising
background image

336

INTELLIGENT ACTUATOR

Appendix

1. I/O

Parameters

No. Parameter

name

Default value

(Reference)

Input

range

Unit

Remarks

1 I/O port assignment

type

1

0 ~ 20

0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 (standard I/O) ~ * Ports

are assigned only for the installed adjoining slots, starting from
slot 1 = For safety reasons)

2 Input port start

number with fixed
standard I/O
assignments (I/O1)

000

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

3 Output port start

number with fixed
standard I/O
assignments (I/O1)

300

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

4 Input port start

number with fixed
expanded I/O1
assignments (I/O2)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set) (Slot next to the
standard I/O slot)

5 Output port start

number with fixed
expanded I/O1
assignments (I/O2)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

6 Input port start

number with fixed
expanded I/O2
assignments (I/O3)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

7 Output port start

number with fixed
expanded I/O2
assignments (I/O3)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

8 Input port start

number with fixed
expanded I/O3
assignments (I/O4)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

9 Output port start

number with fixed
expanded I/O3
assignments (I/O4)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

10 Standard I/O error

monitor (I/O1)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

* Some exceptions apply.

11 Expanded I/O1 error

monitor (I/O2)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

* Some exceptions apply.
(Slot next to the standard I/O slot) * Some exceptions apply.

12 Expanded I/O2 error

monitor (I/O3)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

* Some exceptions apply.