IAI America XSEL-KET User Manual

Page 168

Advertising
background image

149

Part 4 Commands

INTELLIGENT ACTUATOR



GDCL (Get deceleration data)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

GDCL

Variable

number

Position

number

CP

[Function] Obtain deceleration data from the deceleration item in the position data specified in operand

2, and set the value in the variable specified in operand 1.


[Example]

GDCL

100

10

Set the deceleration data at position No. 10 in variable 100.


Position No.

Axis 1

Axis 2

Axis 3

Vel

Acc

Dcl

1 XXX.XXX

XXX.XXX

XXX.XXX

XXX

X.XX

X.XX

2 XXX.XXX

XXX.XXX

XXX.XXX

XXX

X.XX

X.XX




10 50.000

100.000

150.000

200

0.30

0.30



If the position data is set as above when the command is executed, 0.3 will be set in variable 100.