IAI America XSEL-KET User Manual

Page 187

Advertising
background image

168

Part 4 Commands

INTELLIGENT ACTUATOR



MOVP (Move PTP by specifying position data)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

MOVP

Position

number

Prohibited PE

[Function] Move the actuator to the position corresponding to the position number specified in operand

1, without interpolation (PTP stands for “Point-to-Point”).
The output will turn OFF at the start of axis movement, and turn ON when the movement is
complete.


[Example 1]

VEL

100

Set the speed to 100 mm/sec.

MOVP

1

Move the axes to the position corresponding to position No.
1 (200, 100).

[Example 2]

VEL

100

Set the speed to 100 mm/sec.

LET

1

2

Assign 2 to variable 1.

MOVP

*1

Move the axes to the position corresponding to the content
of variable 1 (position No. 2, or (100, 100)).


No. X-axis Y-axis Speed

Acceleration

Deceleration

1 200.000 100.000 XXX XXXX

XXXX

2 100.000 100.000 XXX XXXX

XXXX



Travel path from the home to the position corresponding to position No. 1 (200, 100)




















X-axis

Y-axis

Only the Y-axis completes
movement.

Each axis moves at
the specified speed.

Origin 0

100 mm

100 mm

200 mm

Advertising