11

External source mode

1

(CW time sweep only)

Frequency range

300 kHz to 6 GHz

R-channel input requirements (typical)

Power level

0 to -25 dBm

Spectral purity

Maximum

<-30 dBc

spurious input

Residual FM

<20 kHz

Typical settling time

500 ms (automatic)
50 ms (manual)

Frequency readout accuracy 0.1% (automatic)
Input frequency accuracy requirement

2

Manual

-0.5 to 5 MHz

Accuracy

(see magnitude and phase
characteristics)

Magnitude Characteristics

Dynamic accuracy

(10 Hz IF BW)

Display resolution

0.001 dB/division

Marker resolution

3

0.001 dB

Trace noise
(+5 dBm at test-port, ratio measurement, 3 kHz BW)

300 kHz to 3 GHz

<0.006 dB rms

3 GHz to 6 GHz

<0.010 dB rms

Reference level

Range

±500 dB

Resolution

0.001 dB

Stability

2

30 kHz to 3 GHz

0.02 dB/° C

3 GHz to 6 GHz

0.04 dB/° C

Phase Characteristics

Dynamic accuracy

(10 Hz IF BW)

Range

±180°

Display resolution

0.01°/division

Marker resolution

3

0.01°

Trace noise
(+5 dBm at test-port, ratio measurement, 3 kHz BW)
300 kHz to 3 GHz

<0.038° rms

3 GHz to 6 GHz

<0.070° rms

Reference level

Range

-180° to +180°

Resolution

0.01°

Stability

30 kHz to 3 GHz

0.05°/° C

3 GHz to 6 GHz

0.20°/° C

Polar characteristics

Range

10 x 10

–12

to 1000 units

full scale

Reference

±500 units

1. See the Agilent 8753ES descriptions and options for a functional description.

Measurement accuracy is dependent on the stability of the input signal.

2. Typical performance.
3. Marker resolution for magnitude; phase and delay is dependent upon measured

value. Resolution is limited to five digits.