Dispenser & Reader Specific Installation

Tokheim Electronic Dispenser

Note all warnings at the beginning of installation section.

Instructions for DBox installations in this manual are for the specific DBoxes supplied by dispenser manufacturers. If using DBoxes
supplied by Progressive International, refer to the Installation Guide which accompanies PIE’s DBox.

PIE normally ships Tokheim-standard communications style configurators. A 67B DBox must be either converted or have appropriate
RS422 configurators and cable (supplied by PIE). If converting an RS422 67B DBox to Tokheim-standard communication, contact your
Tokheim representative.

Following instructions on preceding pages of installation section of this manual, install PCXZ and
configurator box(es). Then, follow specific instructions for connecting PCXZ system to the appropriate
Tokheim DBox. Refer to Diagram: PCXZ to Tokheim 67 DBox and Diagram: PCXZ to Tokheim 98/94 Power Center following this
section and Diagram: PCXZ to Two Tokheim 98/94 Power Centers later in this section.

1.

After installing the PCXZ, configurator box(es) and cabling according to the directions in this
document, follow Tokheim’s installation instructions and install dispensers.

For Dispensers Using Model 98/94 Computer/Power Center

(See next page for dispensers using Model 67 or 67B DBox.)

2.

Install the Model 98/94 Computer/Power Center box according to Tokheim’s installation
manual. Dispensers must work in stand-alone before proceeding. Program dispensers as if connecting
to a Tokheim Model 179 or Model 184 Console.

3.

Locate dispenser connection cable (with DB9S hooded connector on one end and a round
connector on the other end).

4.

Connect the dispenser connection cable to the connector on the Tokheim configurator box.

Screw-lock this connector to the box with screws provided.

For systems with 8 dispensers or less — Connect the dispenser connection cable directly to
the Model 98/94 Computer/Power Center.

For systems with more than 8 dispensers (2 Model 98/94 Computer/Power Centers), —
Use a “Y” cable between the configurator box cable and the Model 98/94 Computer/Power
Centers.

Cables must be screw-locked together. The connection must be in a sheltered
environment, protected from harsh elements such as water, extreme heat or cold.