Dispenser & reader specific installation – Progressive International Electronics PCXZ User Manual

Page 33

Advertising
background image

Progressive International Electronics

PCXZ

Version 4.2/April 2005

Page 25

PCXZinstall

System Installation

Dispenser & Reader Specific Installation

Kraus Electronic Dispenser

Note all warnings at the beginning of installation section.

Instructions for DBox installations in this manual are for the specific DBoxes supplied by dispenser manufacturers. If using DBoxes
supplied by Progressive International, refer to the Installation Guide which accompanies PIE’s DBox.

The following Kraus models must have the minimum version of software noted to work properly with
Progressive equipment:

Micon 100
152 printed circuit board

versions 3.1 & 3.2

252 printed circuit board

version 6.30

463 PLCC processor

version 7.03

Micon 200

version 1.09

Micon 300

version 2.04

Micon 500

to be announced

Following instructions on preceding pages of installation section of this manual, install PCXZ and
configurator box(es). Then, follow specific instructions for connecting PCXZ system to the appropriate
Kraus DBox.

1.

Connect the data communication wires from the Kraus dispenser into the dispenser
connectors on the PIE Kraus Configurator board. See Diagram: PCXZ to Kraus Electronic Dispensers which
follows.
Note that there are three data communication wires connecting to a Kraus dispenser.
They are labeled as follows:

TTC Talk to Console/Kraus dispenser transmit data
TTP Talk to Dispenser/Kraus dispenser receive data
DDC Data Common / Kraus dispenser ground

2.

Note the layout of the Kraus dispenser head. Refer to Diagram: Kraus Dispenser Head Layout.

3.

If submerged turbine dispensers are used, install according to Kraus dispenser installation
instructions or install optional PIE relay control box. See Diagram: Kraus Turbine Dispenser Layout at end of
this section.