Page 18

PCXZinstall

System Installation

Dispenser & Reader Specific Installation

Schlumberger Electronic Dispenser

Note all warnings at the beginning of installation section.

Instructions for DBox installations in this manual are for the specific DBoxes supplied by dispenser manufacturers. If using DBoxes
supplied by Progressive International, refer to the Installation Guide which accompanies PIE’s DBox.

Following instructions on preceding pages of installation section of this manual, install PCXZ and
configurator box(es). Then, follow specific instructions for connecting PCXZ system to the
Schlumberger/SAM dispenser system. Refer to Diagram: PCXZ to Schlumberger Electronic Dispenser which follows.

1.

First, make sure that the Schlumberger dispensers are attached to a Schlumberger Access
Module (SAM). The PCXZ controllers are designed to communicate and control
Schlumberger dispensers through the Schlumberger Access Module (SAM).

2.

Connect the output of the PIE Schlumberger Configurator to the POS1 connector (dispenser
port) on the SAM with the cable provided by PIE.

3.

For more reliable communication, ensure that SAM is set for 4800 baud for dispenser port
and RS232 config is set to 4800.

When programming the dispenser, refer to the Schlumberger Dispenser Option 98 Programming Example later in this section.

Diagram: PCXZ to Schlumberger Electronic Dispenser