Dispenser control center demo test program – Progressive International Electronics PCXZ User Manual

Page 43

Advertising
background image

Progressive International Electronics

PCXZ

Version 4.2/April 2005

Page 35

PCXZinstall

Diagnostics

Dispenser Control Center Demo Test Program

Progressive International Electronics’ PCC Demo Test Program simulates a generic POS application
program. It may be used for both demonstrations and field diagnostics. The PCC Demo Test
Program is provided on the same disk as the Dispenser Simulator Program, and is loaded on a
second computer.

Loading the PCC Demo Test Program

For the PCC Demo Test Program to operate correctly, the ANSI.SYS screen driver must also
be loaded on the computer. If this driver is not installed, locate the ANSI.SYS file on your
computer, add the following line to the CONFIG.SYS file and reboot the computer.

DEVICE=C:\[path]\ANSI.SYS

The programs on the distribution disk should be copied into a subdirectory on the hard drive.
This may be accomplished by creating a subdirectory (i.e., PCC) and copying all the files to
the subdirectory. The files to be copied to the subdirectory are as follows.

PCC.EXE
PCC_SERL.EXE
SYSTEM.DAT

To start the PCC program, first execute the DOS TSR driver for the controller. The driver used
for Progressive’s controllers is:

PCC_SERL
(sets Comm 1, 9600 baud, INT Vector 60)
PCC_SERL P2F8 i3
(sets Comm 2, 9600 baud, INT vector 60)

For extended settings for PCC_Serl, view the readme.txt file on the PCC Demo Disk.

Next, execute PCC.EXE.

Main Screen

F1 = Help
F2 = Set up the PC port
F3 = Operator mode
F4 = Program mode
F5 = Read the error
F6 = Reset the PCC
F7 = Set printer
F9 = Set screen
F10 = Exit to DOS
Select the Function: