1. The following table gives the Non-incendive Circuit Parameters:

The Entity Concept allows interconnection of non-incendive apparatus with
associated apparatus – not specifically examined combinations – as a system when
the approved values of V

oc

(or U

o

) and I

sc

(or I

o

) for the associated apparatus are

less than or equal to Vmax (U

i

) and Imax (I

i

) for the non-incendive apparatus, and

the approved values of C

a

(C

o

) and L

a

(L

o

) for the associated apparatus are greater

than or equal to C

i

+ C

cable

and L

i

+ L

cable

, respectively, for the non-incendive field

wiring apparatus.

2. Associated Non-incendive Field Wiring Apparatus shall satisfy the following:

3. If the electrical parameters of the cable are unknown, the following values may be
used:

z

C

cable

= 196.85 pF/m (60 pF/ft)

z

L

cable

= 0.656

µH/m (0.20 µH/ft)

4. Wiring methods must be in accordance with the electrical code of the country in
use.

The Industrial Personal Computer must be installed in an enclosure. If installed in a
Class I, Division 2 Location, the enclosure must be capable of accepting one or
more Division 2 wiring methods.

Circuit Parameters

USB ports 1 and 3 USB ports 2 and 4 USB port 5

Open-circuit voltage = V

oc

5.066 V

5.26 V

5.089 V

Short-circuit current = I

sc

1320 mA

830 mA

1322 mA

Associated
capacitance = C

a

20

µF

20

µF

20 µF

Associated inductance = L

a

16.8

µH

16.8

µH

16.8 µH

Industrial Personal Computer

-

Associated Non-incendive Field Wiring
Apparatus (Mouse, Keyboard)

V

oc

I

sc

C

a

L

a




V

max

I

max

C

i

+ C

cable

L

i

+ L

cable

Advertising