Wiring and Connecting the Terminal Block

The table below describes how to connect the power cord to the DC Industrial
Personal Computer:

Marine Certification Connections

If the product is used in an environment requiring marine certification, a power line
filter must be in the power line.

For the Noise Filter for Marine Certification, please refer to "Accessories"
(page. 161).

Step

Action

1

Remove all power from the Industrial Personal Computer and confirm that the
DC power supply has been disconnected from its power source.

2

Remove the terminal block from the power connector and connect the power
cord to the terminal block as shown below:

Use wire with:

z

cross-section 0.75 mm

2

to 2.0 mm

2

(AWG 18 to AWG 14)

z

maximum operating temperature not less than 75

°C (167 °F).

3

Place the terminal block in the power connector and tighten the screws.

NOTE: The recommended torque to tighten these screws is 0.5 N•m (4.5 lb-
in).