Hardware Modifications

126

UPS Battery Unit Description

The UPS battery unit is subject to wear and should be replaced regularly (at least
following the specified lifespan).

The following figure shows the connector of the UPS battery unit:

Features

Values

Battery:
Type
Method

Enersys Cyclon 12 V 5 Ah (6 connected in series)
Single cell (X cell)

Rated Voltage

12 V

Operating Current

Max. 8 A

Deep Discharge Voltage

10 V

Temperature Sensor

NTC resistance

Weight

Approx. 3.2 kg (7.05 lbs)

Ambient Temperature:
Operation
Storage
Transport

– 40 to + 80

°C (– 40 °F to + 176 °F)

– 65 to + 80

°C (– 85 °F to + 176 °F)

– 65 to + 80

°C(– 85 °F to + 176 °F)

Relative Humidity:
Operation
Storage
Transport

5...95%, non-condensing
5...95%, non-condensing
5...95%, non-condensing

Altitude

Max. 3000 meters (9843 feet)

Lifespan

10 years at 25

°C (77 °F) (up to 80% battery capacity)

Maintenance Interval (During
Storage)

Charge once every 6 months

Battery Charging Time at Storage 0
%

15 hours