Industrial Personal Computer Connections

104

RS-232C - Bus length and cable type

The maximum transfer rate of 115 kBit/s depends on the cable type being used.

The material used for the cable should preferably have all or most of the following
properties in order to reach an optimal transfer rate.

Distance [m]

Transfer rate [kBit/s]

≤ 15

Typ. 64

≤ 10

Typ. 115

≤ 5

Typ. 115

RS-232C cable

Property

Signal lines

Cable cross section
Wire insulation
Conductor resistance
Stranding
Shield

4 x 0.16 mm² (26AWG), tinned Cu wire
PE
≤ 82 Ω/km
Wires stranded in pairs
Paired shield with aluminum foil

Grounding line

Cable cross section
Wire insulation
Conductor resistance

1 x 0.34 mm² (22AWG/19), tinned Cu wire
PE
≤ 59 Ω/km

Outer sheathing

Material
Characteristics
Entire shielding

PUR mixture
Halogen free
From tinned cu wires

Advertising