FP3000 Series User Manual

5-8

5.2

Wiring

5.2.1

Connecting the Power Cord

„FP3500-T11/FP3600-T11/FP3650-T41 (Type AC)

‹ Power Cord Specifications

To avoid an electric shock, when connecting the FP’s power cord terminals to the power

terminal block, confirm that the FP’s power supply is completely turned OFF, via a breaker,

or similar unit.

To avoid the dangers of fire, electric hazards and equipment damage, be sure to use only

the specified voltage when operating the FP.

Since there is no power switch on the FP unit, be sure to attach a breaker-type switch to its

power cord.

• To prevent the Ring Terminals

*1

from causing a short when the terminal block

attachment screws are loosened, be sure to use sleeve-type Ring Terminals.

• When the FG terminal is connected, be sure the wire is grounded. Not grounding

the FP unit will result in excessive noise. Use your country’s applicable standard

for grounding.

• The SG and FG terminals are connected internally in the FP unit.

• When connecting the SG line to another device, be sure that the design of the

system/connection does not produce a shorting loop.

*1

Recommended Ring Terminal: Equivalent to V2-MS3 (made by JST)

AC Power Cord

Grounding Wire

Power Cord

Double-Insulation Wire
1.25 mm

2

to 2.0 mm

2

(16 to 14 AWG)

1.25 mm

2

to 2.0 mm

2

(16 to 14 AWG)

Recommended
Ring Terminal

*1

*1

In order to prevent a short circuit caused by loose screws, make sure to use a crimp-

type terminal with insulating sleeve.

V2-MS3 compatible
(J.S.T. Mfg. Co.,Ltd).

V2-P4 compatible
(J.S.T. Mfg. Co.,Ltd).

SEE

5.2.3 Connecting the Power Supply (page5-15)

Over ø3.2 mm[0.13 in.]

Under 6.0 mm
[0.24 in.]

Over ø4.3 mm[0.17 in.]

Under 7.0 mm
[0.28 in.]