5-10

‹ Power connector specification

‹ Wiring

Use the following wiring for FP. Those are Phoenix Contact products.

‹ Power cable connecting

(1)

Make sure that the power cable has no power distribution.

(2)

Remove the power connector from the unit.

(3)

There are three screws located in the center of the connector. Make them loosen.

(4)

Peel some of the outside of shield part, twist core wires, and insert the wire into each cable joint.

+

24V

-

0V

FG

A frame ground terminal connected with FP unit

Kind of power cord is CA5-DCCNL-01 which are Digital products, or GMVSTBW2,5/3-STF-

7,62 which are Phoenix Contact

*1

products.

*1

Please contact Phoenix Contact for the details.

Recommended Drivers

SZF 1-0.6x3.5 (1204517)

Recommended stick end terminal

AI 0.75-8GY (3200519)

AI 1-8RD (3200030)

AI 1.5-8BK (3200043)

AI 2.5-8BU (3200522)

Crimp tool for recommended stick end terminal

CRIMPFOX ZA 3 (1201882)

FG

+

-

Power Cable Joint