2 no display, 2 no display -3 – Proface FP3900 - 19 Flat Panel" User Manual

Page 142

Advertising
background image

Chapter 8 Troubleshooting

8-3

8.1.2

No Display

When the screen does not display when powering up, or if the screen turns OFF by itself, use the flowchart

below to find an appropriate solution.

No Screen Display

Is it using the correct

power voltage?

Turn OFF the power switch.

Is the power supply

cable connected properly

to the unit?

There is a problem with the FP unit. Please
contact your local FP distributor.

Does the backlight (CCFL)

light up?

Connect the appropriate voltage.

SEE

4 Specifications (page4-1)

Fix the power cable connection.

SEE

5 Installation and Wiring (page5-1)

YES

NO

NO

YES

YES

NO

Advertising
This manual is related to the following products: