Chapter 9 Maintenance

9-3

9.1.2

Replacing the Installation Gasket

The installation gasket protects the FP and improves its water resistance. For instructions on installing the FP

unit's gasket, refer to the following page.

„Installation Gasket Replacement Procedure

(1)

Place the FP on a flat, level surface with the display

facing downwards.

(2)

Remove the old gasket from the FP.

(3)

Attach the new gasket to the FP. Be sure to insert the

gasket into the FP unit’s groove so that the gasket’s

groove sides are vertical.

(4)

Check if the gasket is attached to the FP correctly.

The upper surface of the gasket should protrude

approximately 2mm out from the groove.

SEE

5 Installation and Wiring (page5-1)

• A gasket which has been used for a long period of time may have scratches or

dirt on it, and could have lost much of its water resistance. Be sure to change the

gasket at least once a year, or when scratches or dirt become visible.

• The FP unit installation gasket’s model number is as follows.

FP-3500T Series

GP570-WP10-MS

FP-3600T Series

FP-3650T Series

FP-3710T Series

CA3-WPG15-01

FP-3900T Series

CA7-WPG19-01