2 error message, 1 error message list, 2 error message -6 – Proface FP3900 - 19 Flat Panel" User Manual

Page 145: 1 error message list -6, 6 8.2 error message

Advertising
background image

FP3000 Series User Manual

8-6

8.2

Error Message

This section explains the messages that appear when an error has occurred in the

FP unit during RUN mode.The problem causing the error message and its

related countermeasure are explained in the table below.

(Only the latest error message will appear on the FP screen)

8.2.1

Error Message List

Error Message

Problem

Solution

Out of range

Signal timing has been input
that is not compatible with the
FP unit.

Set the FP Output settings so that they match the
PC’s frequency and resolution.

The dot clock has greatly
exceeded of the FP units usable
timing range.

Resolution has been set that is
not compatible with the FP unit.

No signal

The PS-2000B unit or a
Windows-compatible PC's
power has not been turned ON.

Turn on the PS-2000B unit or a Windows-
compatible PC’s power.

The PS-2000B unit or a
Windows-compatible PC has
not been correctly connected to
the FP unit.

Connect the RGB cable/DVI-D cable correctly.