76

Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide

53-1003029-02

Power supply replacement

6

5. Pull the power supply outward once the screws have been unscrewed. This will disconnect the

power supply from the backplane. Pull it completely free of the chassis.

6. Place the power supply in an anti-static bag for storage.

7. Insert a new supply, or place and screw in a cover plate over the empty power supply. Refer to

“Installing a DC power supply”

on page 76 for details.

Installing a DC power supply

DANGER

Before beginning the installation, refer to the precautions in

“Power precautions”

on page 34.

Use the following procedures for DC power supplies in Brocade devices.

Follow the steps given below to install an DC power supply.

1. If necessary, remove the power supply locking screws located in the upper left and the bottom

right of the device.

2. If the empty power supply bay has a cover plate, remove the two screws near the edges of the

cover plate to unlock the plate, then remove the plate.

3. Remove the DC power supply from its packaging (

Figure 53

).

FIGURE 53

The DC power supply

4. Insert the wires into the DC wiring assembly (

Figure 54

).

5. Use the wire tightening screws to secure the wires.

6. Insert the DC connector with wires to the power supply and tighten the two assembly screws.