Gigabit ethernet module, Installation or replacement, Displaying the status of the power supplies – Brocade NetIron CER 2000 Series Hardware Guide (Supporting R05.6.00) User Manual

Page 90

Advertising
background image

80

Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide

53-1003029-02

10-Gigabit Ethernet module installation or replacement

6

The LEDs for Fan, PS1 and PS2 are located on the right side of the front panel for Brocade NetIron
CES 2000 Series and NetIron CER 2000 Series 2024 models (On the Brocade NetIron CES 2000
Series 2048 and NetIron CER 2000 Series 2048 models, these LEDs are located on the left side of
the front panel).

The software regularly polls the hardware for power status information. You can display the status
information from any management session. In addition, the software automatically generates a
Syslog message and SNMP trap if a status change occurs.

Displaying the status of the power supplies

You can display the status of the power supplies by entering the show chassis command at any
level of the CLI. The display shows whether a power supply is installed in the specified power supply
slot and the status of the power supply. If you are not already attached to a terminal or a PC running
terminal emulation, see

“PC or terminal attachment”

on page 49

Brocade> show chassis

*** Brocade NetIron CES 2000 Series 2048CX ***

---POWERS ---

Power 1 ( 3I50 - AC 504W): Installed (OK)

Power 2: not present

Total power budget for system = 504 W

--- FANS ---

Metro fan tray (fan 1): Status = OK, Speed = LOW (50%)

Metro fan tray (fan 2): Status = OK, Speed = LOW (50%)

Metro fan tray (fan 3): Status = OK, Speed = LOW (50%)

Metro fan tray (fan 4): Status = OK, Speed = LOW (50%)

Metro fan tray (fan 5): Status = OK, Speed = LOW (50%)

Metro fan tray (fan 6): Status = OK, Speed = LOW (50%)

--- TEMPERATURE READINGS ---

CPU: Board 32.50C Chip 41.6C

481XG PPCR1: Board 32.50C Chip 43.31C

481XG PPCR2: Board 29.50C Chip 41.93C

2X10G PPCR: Board 33.0C Chip 41.68C

Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds

Base MAC Address = 001b.ed39.0300

Brocade NetIron CES 2000 Series 2048CX>

Syntax: show chassis

10-Gigabit Ethernet module installation or replacement

The 2-port 10-Gigabit Ethernet modules may optionally be installed or replaced in the field on the
Brocade NetIron CES 2000 Series 2024C, Brocade NetIron CES 2000 Series 2024F, NetIron CER
2000 Series 2024C, NetIron CER 2000 Series 2024F units. You can order the Brocade

device

with a 2 x10-Gigabit module installed at the factory, or you can upgrade your device later.

This section provides the steps for installing, removing, and replacing the 10-Gigabit Ethernet
module. You will need the following tools to perform these procedures:

#2 Phillips-head screwdriver

Electrostatic Discharge (ESD) kit