Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide

77

53-1003029-02

Power supply replacement

6

FIGURE 54

The DC wiring assembly

7. With one hand, hold the bar on the front panel of the power supply. With the other hand,

support the underside of the power supply, and insert the power supply into the empty power
supply slot. Press until the supply is completely in the slot, so that the connectors on the back
of the supply are fully engaged with the pins on the power backplane (

Figure 50

).

CAUTION

Make sure you insert the power supply right-side up. It is possible to insert the supply upside
down, although the supply will not engage with the power backplane when upside down. The
power supply is right-side up when the manufacturer label is on the top.

8. Secure the two screws near the edges of the supply to lock the supply in place (

Figure 55

).

1

Wire tightening screws

2

Assembly screws