6 load cell wiring, Figure 2-5. j1 load cell connector-facing, Figure 2-6. load cell wiring – Rice Lake Condec UMC600IS User Manual

Page 11: Table 2-6. load cell connector pin assignments

Advertising
background image

8

UMC 600IS Installation Manual

2.6

Load Cell Wiring

All units are equipped with a six-wire load cell
connector. Condec supplies load cell cable in various
lengths (see Table 2-3 on page 5). One end of the
cable attaches to the indicator; the other end has
stripped and tinned wires for connection to a junction
box. The UMC 600IS is supplied with a blank six-pin
connector that can be attached to existing load cell
cables by the installer.

Figure 2-5 shows the load cell output connector and
the location of J1 on the back of the indicator.
Ta b l e 2 - 6 s h ow s t h e l o a d c e l l c o n n e c t o r p i n
assignments.

Figure 2-5. J1 Load Cell Connector-facing

For four-wire load cell connections, short the sense
lines to the excitation lines as shown in Figure 2-6.

Figure 2-6. Load Cell Wiring

J1

J2

J3

J1

Load Cell
Connector

A

B

C

D

E

F

Pin

Function

A

+EXCITATION

B

–EXCITATION

C

+SIGNAL

D

–SIGNAL

E

+SENSE

F

–SENSE

Table 2-6. Load Cell Connector Pin Assignments

E

A

C

B

F

D

+SEN

+EXC

+SIG

–EXC

–SEN

–SIG

P1

Check load cell color
code for proper wiring

No connection

Connector shell or chassis ground

A

B

C

D

E

F

Six-Pin Female

P1

Jumper wires

A (+EXC) to E (+SEN)
B (–EXC) to F (–SEN)

4-Wire Configuration

6-Wire Configuration

A

B

C

D

E

F

Advertising