UMC 600IS Installation Manual

6.4

Specifications

Power

Power Input

Intrinsically safe power supply (7.5 VDC
output) or optional 6 VDC battery

Analog Specifications

Full Scale Input Signal

Up to 45 mV

Load Cell Excitation

5 VDC, fixed

Load Cell Current

60 mA (4 x 350 Ω load cells)

Load Cell Cabling

6-wire configuration with
remote sensing

Analog Signal Input Range

0.7 mV/V to 3.2 mV/V

Analog Signal Sensitivity

0.3 µV/graduation

Resolution

10 000 dd (NTEP), 80 000

expanded

Measurement Rate

10 measurements/sec

Display Increments

1, 2, 5, 10, 20, 50, 100

Decimal Point

0, 0.0, 0.00, 0.000, 0.0000

AZM (Zero Tracking)

Gross

mode

only:

configurable to ±0.5 grads,
±1.0 grads, ±3.0 grads, or off

PAZ and ATM Aperture

Configurable to ±1.9% or
100% of full scale

Motion

Band

Configurable to ±1 or ±3

grads; 1-second delay or no
delay

Calibration

Method

Software, with optional

five-point linearization

Serial Communications

Port 1

Full duplex 20 mA at 9600, 4800, 2400, 1200,
600, or 300 bps

Operator Interface

Display

6-digit LED display. 7-segment, .6 in (15
mm) digits

Annunciators

Center of zero, Gross, Net, Motion, lb/kg

Keyboard

21-key flat membrane panel with 0–9
numeric keys, ENT (Enter), CE (Clear Entry),
ZERO, GROSS/NET, TARE, TARE RECALL,
PRINT, lb/kg CONV, SP1, SP2, ON/OFF

Environmental

Operating Temperature

–10 to +40 °C (14 °F to 104 °F)

Enclosure

Enclosure Dimensions

9.0 in x 6.44 in x 4.0 in
23 cm x 16 cm x 10 cm
See Figure 6-1 on page 41

Rating/Material

NEMA 4X, stainless steel

Certifications and Approvals

NTEP
CoC Number

89-023A299-010

Accuracy Class

III/III L
n

max

: 10 000

FM #0Z0AZ.AX

N

A

T

IO

NA

L CONFE