6.1

Error and Status Messages

The UMC 600IS indicator provides a number of error and status messages. When an error occurs, the message is
shown on the indicator display. Table 6-1 lists these messages and their meanings.

Error Message

Description

Solution

Err1

Loss of configuration

Reconfigure

Err1a

Loss of option configuration

Err1b

Err1c

Err2

Loss of zero calibration

Recalibrate

Err3

Loss of span calibration

Err5

Loss of auto tare

Acquire tare

Err6

Loss of auto zero

Acquire zero

Err9

Not in span calibration

Program span value before entering

Err 10H

Input > 3.3 mV/V at full scale

Recalibrate span to set full scale in the range 0.4–3.3 mV/V

Err 10L

Input < 0.4 mV/V at full scale

Err 10P

PTZ (push to zero) > 2%

Perform zero calibration

Err 10–

PTZ > weight used for span calibration

OL

Gross overload

Check load cell wiring

UL

Gross underrange

CAL

Calibration successful

Table 6-1. UMC 600IS Error and Status Messages