UMC 600IS Installation Manual

2.3

AC Power Wiring

Standard units are powered by 115 VAC into Condec
DC output power supply (Condec PN 58805).

2.4

Battery Option

The battery operated version of the UMC 600IS is
powered by a 6-volt 10-ampere-hour battery that is
enclosed in a stainless steel housing. It is mounted
below the indicator and is removable for charging in
the safe area.

Caution should be used when
considering a battery powered unit for
control applications where a
discharged battery would cause
serious problems.

The battery is approved for use in hazardous
environments and provides up to 51 hours of
continuous operation in a four by 350

load cell

system. Table 2-4 illustrates estimated operating
times based on a fully charged battery.

The battery pack is ideal for limited use operations
such as bench scales and platform scales. A low
battery LED annunciator indicates when the battery
n e e d s t o b e r e c h a rg e d ( s e e F i g u r e 2 - 2 ) . T h e
recommended initial battery charge time is 10 hours.

Figure 2-2. Low Battery LED Annunciator

The battery pack is designed for easy removal and can
be recharged in a safe area in eight hours or less. The
indicator also contains a programmable auto shutoff to
power off the indicator when not in use.

All wiring must be done by qualified
personnel and meet all appropriate
safety and NEC electrical codes as
noted on Condec Control Drawing
33476.

2.4.1

Modes of Operation

The UMC 600IS battery powered unit has three
modes of operation:

Push on-off (controlled from the front panel
on button).

Push on with auto turn off after selected time
(one to nine minutes).

Auto turn off, same as above with restart of
time cycle if motion is detected on the scale
(prevents the scale from turning off while in
use).

2.4.2

Configuration for Battery Operation

The configuration for battery operation is as follows:

1. The clock function in Option 3 must be

enabled and set if Option 4 is to be used (see
Section 3.3.3 on page 22).

2. Option 4 must be set as follows (see Section

3.3.4 on page 23 for further details).

Load Cell Size

Quantity of cells

Operating Time

350

load cell

1

70 hours

2

62 hours

3

56 hours

4

51 hours

700

load cell

1

74 hours

2

70 hours

3

66 hours

4

62 hours

Table 2-4. Operating Time

!

Caution

1

6

2

7

3

8

4

9

5

0

CE

ENT

TARE

RECALL

ZERO

NET

GROSS

TARE

lb/kg

CONV

PRINT

1 SET

POINT

2 SET

POINT

CAPACITY

600 x 0.1

ZERO

NET

GROSS

lb

kg

MOTION

Low Battery Annunciator

A. Option 4 off (unit operates as push on - push off)

B. Option 4 on (the turn off timer is enabled)

C. Parameter 4.1 selects the turn off time (1 to 9 minutes)

D. Parameter 4.2 set to off runs normally/turns off at end of
time cycle.

E. Parameter 4.2 set to on will restart timing function when
unit is timing and motion is detected on the scale.

Table 2-5. Configuration of Battery Operation

!