Rice Lake Condec UMC600IS User Manual
Page 17
Advertising
14
UMC 600IS Installation Manual
Prompt Display
Interpretation
Notes
Digital Averaging
No.
Averages
Update
Rate
5
1
1
10/sec
5
2
2
5/sec
5
4
4
2.5/sec
5
8
8
1 sec
5
16
16
2 sec
5
32
32
4 sec
5
A1
8-4-2
Variable
5
A2
16-8-2
Variable
Tare Enable
Selection of either fixed tare (Ft) or fixed tare and auto tare (both) in Parameter 6
allows up to a six digit fixed tare entry to be made using the numeric front panel
keys or, when configured for full duplex serial communication, a fixed tare entry
can be down loaded through the serial port.
6
Atnr
Auto (stored) tare only
– no recall
6
AUto
Auto (stored) tare only
6
Ft
Fixed (manual) tare
only
6
both
Auto or fixed tare
AZM Capture Band (Displayed Grads)
7
oFF
Off
7
0.5
±0.5
7
1
±1.0
7
3
±3.0
7
5
±5.0
7
10
±10.0
Table 3-4. Configuration Display Prompts 5 – 7