Normal Weighing Mode Operations

35

5.6.2

Demand Mode versus Continuous Data Output

Demand mode is used to interface with printers and
requires a manual Print command from the front panel
t o i n i t i a t e t h e o u t p u t d a t a . To c o m p l y w i t h
legal-for-trade regulations, demand output data is
inhibited during the following conditions:

Scale in motion

Positive overload

Negative overload

Negative gross weight displayed

Unit in display check mode

NOTE:

In legal-for-trade applications, the Motion

Detection Parameter (Parameter 9) must be turned ON.

In demand mode, the operator may choose to print
Gross/Tare/Net when in net mode. If the serial port is
set to Print on Demand mode, the format is:

<STX><POL><DATA><SP><LB/KG><SP><GR/NT>
<SP><CR><LF>

General Continuous Mode Output Data Format

Continuous mode is used to interface to computers,
scoreboards, and other remote devices requiring
c o n s t a n t d a t a u p d a t i n g . C o n t i n u o u s m o d e
transmission occurs at the end of each display update.

<STX><POL><DATA><L/K><G/N><STAT><CR><LF>

Downloading/Recall Commands

The format for fixed tare data entry (see Table 5-5) is:

<FE>(XXXXXX)<CR>

The format for fixed tare data recall (see Table 5-5) is:

<FR>(XXXXXX)<CR>

NOTES:

Response data (xxxxxx) is six characters with
no decimal point, seven with decimal point.
Leading zeroes are shown as space characters.

Invalid data requests or entries are responded
to with an echo of valid portion and the letter
I indicating the invalid portion.

Character

Identification Definition

<,>

Bracket delimiters are not sent

SE

Setpoint entry (53H, 45H)

SR

Setpoint recall (53H, 52H)

FE

Fixed tare entry (46H, 45H)

FR

Fixed tare recall (46H, 45H)

n

Setpoint parameter 0-6

(

Data opening parenthesis (28H)

)

Data closing parenthesis (29H)

CR

Command terminator (0DH)

xxxxxx

DATA characters must be six or less including
decmal point if configured: 999999 or 999.99.
Space and polarity characters can not be used
in fixed tare data entry.

Table 5-5. Data String Characters