LumaSense Technologies LumaSoft Gas Multi Point 7860 User Manual

Page 178

Advertising
background image

Appendix C

_________________________________________________________________________

________________________________________________________________________

BE6027-12

LumaSoft Gas Software

LumaSense Technologies A/S

7810 and 7860

Page 178 of 194

Channel 9 Gas B Alarm H occurred

Boolean Channel9/GasB/AlarmHOccurred/9020300

Channel 9 Gas B Alarm L occurred

Boolean Channel9/GasB/AlarmLOccurred/9020400

Channel 9 Gas B Alarm LL occurred

Boolean Channel9/GasB/AlarmLLOccurred/9020500

Channel 9 Filter B alignment error flag

Boolean Channel9/FilterB/AlignmentErrorFlag/9020600

Channel 9 Gas C Concentration

Float

Channel9/GasC/Concentration/9030100

Channel 9 Gas C Alarm HH occurred

Boolean Channel9/GasC/AlarmHHOccurred/9030200

Channel 9 Gas C Alarm H occurred

Boolean Channel9/GasC/AlarmHOccurred/9030300

Channel 9 Gas C Alarm L occurred

Boolean Channel9/GasC/AlarmLOccurred/9030400

Channel 9 Gas C Alarm LL occurred

Boolean Channel9/GasC/AlarmLLOccurred/9030500

Channel 9 Filter C alignment error flag

Boolean Channel9/FilterC/AlignmentErrorFlag/9030600

Channel 9 Gas D Concentration

Float

Channel9/GasD/Concentration/9040100

Channel 9 Gas D Alarm HH occurred

Boolean Channel9/GasD/AlarmHHOccurred/9040200

Channel 9 Gas D Alarm H occurred

Boolean Channel9/GasD/AlarmHOccurred/9040300

Channel 9 Gas D Alarm L occurred

Boolean Channel9/GasD/AlarmLOccurred/9040400

Channel 9 Gas D Alarm LL occurred

Boolean Channel9/GasD/AlarmLLOccurred/9040500

Channel 9 Filter D alignment error flag

Boolean Channel9/FilterD/AlignmentErrorFlag/9040600

Channel 9 Gas E Concentration

Float

Channel9/GasE/Concentration/9050100

Channel 9 Gas E Alarm HH occurred

Boolean Channel9/GasE/AlarmHHOccurred/9050200

Channel 9 Gas E Alarm H occurred

Boolean Channel9/GasE/AlarmHOccurred/9050300

Channel 9 Gas E Alarm L occurred

Boolean Channel9/GasE/AlarmLOccurred/9050400

Channel 9 Gas E Alarm LL occurred

Boolean Channel9/GasE/AlarmLLOccurred/9050500

Channel 9 Filter E alignment error flag

Boolean Channel9/FilterE/AlignmentErrorFlag/9050600

Channel 9 Gas W Concentration

Float

Channel9/GasW/Concentration/9060100

Channel 9 Gas W Alarm HH occurred

Boolean Channel9/GasW/AlarmHHOccurred/9060200

Channel 9 Gas W Alarm H occurred

Boolean Channel9/GasW/AlarmHOccurred/9060300

Channel 9 Gas W Alarm L occurred

Boolean Channel9/GasW/AlarmLOccurred/9060400

Channel 9 Gas W Alarm LL occurred

Boolean Channel9/GasW/AlarmLLOccurred/9060500

Channel 9 Filter W alignment error flag

Boolean Channel9/FilterW/AlignmentErrorFlag/9060600

Channel 9 Pressure

Float

Channel9/Pressure/9500100

Channel 9 Gas Monitor Air flag

Boolean Channel9/GasMonitor/Airflag/9500200

Channel 9 Gas Monitor Error flag

Boolean Channel9/GasMonitor/Errorflag/9500300

Channel 9 Gas Monitor Warning flag

Boolean Channel9/GasMonitor/Warningflag/9500400

Channel 9 Monitor Display Error Message

String

Channel9/GasMonitor/MonitorDisplayErrorMessage/9500500

Channel 9 Monitor Display Warning Message

String

Channel9/GasMonitor/MonitorDisplayWarningMessage/9500600

Channel 9 Multiplexer error flag

Boolean Channel9/Multiplexer/errorflag/9600100

Channel 9 Multiplexer warning flag

Boolean Channel9/Multiplexer/warningflag/9600200

Channel 9 Multiplexer error number

Long

Channel9/Multiplexer/errornumber/9600300

Channel 9 Multiplexer warning number

Long

Channel9/Multiplexer/warning number/9600400

Channel 9 Multiplexer Error Description

String

Channel9/Multiplexer/ErrorDescription/9600600

Channel 9 Multiplexer Warning Description

String

Channel9/Multiplexer/WarningDescription/9600700

Channel 10 Gas A Concentration

Float

Channel10/GasA/Concentration/10010100

Channel 10 Gas A Alarm HH occurred

Boolean Channel10/GasA/AlarmHHOccurred/10010200

Channel 10 Gas A Alarm H occurred

Boolean Channel10/GasA/AlarmHOccurred/10010300

Channel 10 Gas A Alarm L occurred

Boolean Channel10/GasA/AlarmLOccurred/10010400

Channel 10 Gas A Alarm LL occurred

Boolean Channel10/GasA/AlarmLLOccurred/10010500

Channel 10 Filter A alignment error flag

Boolean Channel10/FilterA/AlignmentErrorFlag/10010600

Channel 10 Gas B Concentration

Float

Channel10/GasB/Concentration/10020100

Channel 10 Gas B Alarm HH occurred

Boolean Channel10/GasB/AlarmHHOccurred/10020200

Channel 10 Gas B Alarm H occurred

Boolean Channel10/GasB/AlarmHOccurred/10020300

Channel 10 Gas B Alarm L occurred

Boolean Channel10/GasB/AlarmLOccurred/10020400

Channel 10 Gas B Alarm LL occurred

Boolean Channel10/GasB/AlarmLLOccurred/10020500

Channel 10 Filter B alignment error flag

Boolean Channel10/FilterB/AlignmentErrorFlag/10020600

Advertising