Triton RL2000 User Manual User Manual

Page 113

Advertising
background image

387

Dispenser offline - error-validating
configuration

Dispenser failed to identify the dispenser type installed.
1. Verify all connectors to the dispenser mechanism.
2. Restart operating system. Clear terminal error code.
3. If error persists, replace the dispenser mechanism or the CMC of an NMD
dispenser

388

Dispenser offline - NMD require Reject
Vault and at least one cassette

Verify that the Reject Vault and one cassette are present in the dispenser
mechanism. Clear terminal error code. If error persists, replace the dispenser
mechanism

389

Dispenser offline. Detected offline error
check op state

Restart the operating system. Verify the error code lights on the dispenser are
operating in proper sequence. Use the NMD test software (available to Triton
Certified Service Technicians) and verify the operational error code of the
dispenser.

390

Dispenser offline - storing configuration Restart the operating system. Verify the error code lights on the dispenser are

operating in proper sequence. Use the NMD test software (avail able to Triton
Certified Service Technicians) and verify the operational error code of the
dispenser.

391

Dispenser sensor failure 2

Access the management function diagnostics menus to verify the operational
error code of dispenser mechanism sensors. Clean sensors as needed.
Replace dispenser components or dispenser if the error persists.

392

Error in last dispense

Check operational error code of dispenser. This problem may be
resolved by replacing the CMC board or by replacing the dispenser
mechanism.

393

Error in double detect 2

394

Purge failed upon power-up

395

Multiple cassette of the same type

NMD dispenser allows for only one of each cassette ID to be installed. Verify
each cassette ID. Replace cassette or Inject New Cassette ID.

396

Dispenser offline – found no reject
bin

500

SPED Read Error

Verify all SPED connections. Restart the operating system. Clear any errors
conditions. Inspect the battery for a voltage reading of greater than 2.8 VDC.
Replace SPED battery is below 2.8 VDC. Replace SPED module if error
persists.

501

SPED invalid return record

Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.

502

SPED read type error

Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.

503

SPED invalid command

Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.

504

SPED invalid return ID

Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.

505

SPED device busy

Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.

506

SPED invalid request

Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.