C5

E

LECTRONIC

LOCKS

AND

B

ATTERY

Reinstate User

(Manager feature only)

Always perform this operation with the door open

1.

Enter Manager Code and HOLD DOWN LAST DIGIT OF CODE until the lock signals with two (2)

sets of double beeps.

2.

PRESS 1. Lock signals once. User is now reinstated.

3.

If a mistake is made, wait thirty (30) seconds and repeat steps 1 - 2.

Remove User

(Manager feature only)

Always perform this operation with the door open

1.

Enter Manager Code and HOLD DOWN LAST DIGIT OF CODE until the lock signals with two (2)

sets of double beeps.
2.

PRESS 3. Lock signals once. User is now permanently removed.

3.

If a mistake is made, wait thirty (30) seconds and repeat steps 1 - 2.

Dual Code Operation

(if feature is programmed)

Always perform this operation with the door open

1.

Must add second user to open lock (See ADD USER).

• Second user CANNOT be Disabled or Removed.

2. After

fi rst code is entered, second code must be entered within ten (10) seconds.

3.

Both codes required to open lock in Open period.

Silent Signal Alarm

(if feature is programmed AND optional Alarm Box is connected to an alarm system)

Always perform this operation with the door open

1.

Enter last digit of code one (1) number higher or one (1) number lower.

Example: Code: 1-2-3-4-5-6

Duress: 1-2-3-4-5-5 or 1-2-3-4-5-7

2.

The lock will open without any indication that the duress signal has been sent.

Time Delay

(if feature is programmed)

Always perform this operation with the door open

1.

Enter valid code.

• Time Delay period starts (1-99 minutes pre-programmed).

• LED fl ashes RED at one (1) second intervals.

- If valid code entered during delay, Time Delay period restarts.

- If invalid code(s) entered during delay, Time Delay period aborts.

2.

At end of Time Delay period, Open period starts (1-19 minutes pre-programmed).

• LED fl ashes RED at 1/2 second intervals.

• Lock beeps at ten (10) second intervals

3.

During Open period, enter valid code(s).

• If invalid code entered during open, Open period continues.

• If four (4) consecutive invalid codes entered, WRONG TRY PENALTY starts.

Time Delay Override

(if feature is programmed)

Always perform this operation with the door open

1.

Must add second code (See ADD USER).

• Second user CANNOT be Disabled or Removed.

2.

Entry of Time Delay Override code during Delay period will open lock.