Security module dev port setup

Inspect cable from main board assembly to the security module for damage.
Make sure that the cable is connected at both ends. Restart ATM. Clear the
error. If error persists, replace the security module.

571

Invalid default transaction

TBD

572

SPED key from pad cmd aborted by
user

Inspect cable from docking board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Restart ATM. Clear the
error. If error persists, it may be necessary to replace the main board, the
docking board, the SPED module or related cabling.

573

SPED keys from pad cmd verify failed

Inspect cable from docking board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Restart ATM. Clear the error. If error persists, it may be necessary
to replace the main board, the docking board, the SPED module or
related cabling.

574

SNA comms error

To be determined

575

Timeout waiting to send command to
dispenser

Inspect the serial communication cables from the main board assembly to the
dispenser for damage. Make sure that each end of the cable is connected
securely. Replace the cable if it appear damaged. Check the power supply
for the proper DC operating voltages and that they are applied to the
dispenser mechanism. Possible defective components include main board
assembly, the docking board, the serial communications cables, the DC power
cables, the power supply, and the dispenser mechanism.

576

Timeout waiting to receive response
from dispenser

Inspect the serial communication cables from the main board assembly to the
dispenser for damage. Make sure that each end of the cable is connected
securely. Replace the cable if it appear damaged. Check the power supply
for the proper DC operating voltages and that they are applied to the
dispenser mechanism. Possible defective components include main board
assembly, the docking board, the serial communications cables, the DC power
cables, the power supply, and the dispenser mechanism.

577

Card reader disabled

Inspect card reader cable. Inspect the card reader for foreign objects.
Replace the cable or clean the card reader as needed. Clear the error.
Restart the ATM. If the error persists, replace the card reader.

578

Card reader present timeout

Inspect card reader cable. Inspect the card reader for foreign objects.
Replace the cable or clean the card reader as needed. Clear the error.
Restart the ATM. If the error persists, replace the card reader.

579

SPED - Enable keypad command failed Inspect cable from docking assembly to the SPED Module for damage. Make

sure that the cable is connected at both ends. Verify that the DC operating
voltages are correct. Restart ATM. Clear the error. If error persists, replace
the SPED module.

580

SPED - Disable keypad command failed

Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.

581

SPED - Enable key from pad module
failed

Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.

582

SPED - Disable key from pad module

Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.

583

SPED - Enable PIN entry mode failed

Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.

584

SPED - Disable PIN entry mode failed

Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.