Specification – KYORITSU 6201A User Manual
Page 11
— 9 —
4. Specification
4.1 General specification, measuring range and accuracy
Voltage(VOLT) measurement of main power supply
Measuring range
207 ~ 264V AC
Resolution
1V
Accuracy
± (2%rdg+3dgt)
Measurement of Protective conductor resistance(RPE)
Measuring range
0 ~ 15.00Ω
Resolution
10mΩ
Open-circuit voltage
<AC12V
Measuring current
10A AC nominal value
Accuracy
± (3%rdg+5dgt)
Measurement of Insulation resistance (RINS)
Rating
250V/20MΩ and 500V / 20MΩ
Measuring range
0.1~19.99MΩ
Resolution
10kΩ
Rated voltage
250V/500V DC(+20%/-10%) @1MΩ
Short-circuit current
2.5mA DC or less
Accuracy
± (2% rdg+3dgt)
Leakage current test
Measuring range
AC0.1~ 19.99mArms
Resolution
0.01mA
Accuracy
±(3%rdg ± 5dgt)
Examination time
Max 15 seconds
Note: For MOV appliances use Leakage Current test.
4.2 Threshold and display
Equipment
Protective conductor
resistance
Insulation
resistance
Leakage
current
Class I
RPE
=
<
1Ω
RINS
>
=
1MΩ
IEL
=
<
5mA
Class II
RINS
>
=
1MΩ
IEL
=
<
1mA
Extension Leads
RPE
=
<
1Ω
RINS
>
=
1MΩ
IEL
=
<
1mA