Proseries, Sonic-pro, 3 startup state – Blue-White Sonic-Pro Hybrid Ultrasonic Flowmeters User Manual

Page 21: Page 21, Circuit board layout, Model s1 model s2 model s3

Advertising
background image

Page 21

Sonic-Pro

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

TM

RS232

USB

ETHERNET

RS485

PROCESS CONTROL RELAYS

(THREE EACH) 10A 250V AC

R1

R2

R3

COM

NC
NO

COM

NC
NO

COM

NC
NO

TRANSDUCER

INPUTS

Tx 1

Tx 2

RED (+)

RED (+)

BLK (-)

BLK (-)

GRN

GRN

mA

Hz

POS (+)

NEG (-)

GRN

SIGNAL

OUTPUTS

NEG (-)

POS (+)

DC

AC

DC (+)

DC (-)

GRN

AC LINE

AC NTRL

POWER INPUT

SD CARD

DATA LOG
(REMOVE)

MODE SWITCH

T

D

INDICATOR

LIGHTS

COMMUNICATIONS

CONNECTOR PANEL

WARNING

INPUT POWER

LIMITS

AC INPUT

96VAC - 264VAC

50/60 Hz

DC INPUT

15 to 30 VDC

SETUP BUTTON

1A 250V (5 x 20)

FUSE

CAUTION

risk of electric shock

RED (+)

BLK (-)

GRN

CIRCUIT BOARD LAYOUT

SETUP BUTTON (white)

When power is applied, the flowmeter enters the Startup state. In the Startup State, the
flowmeter waits for up to 7 seconds for the Setup button to be pressed at which time the
Setup mode is entered and changes to the configuration can be made. If the setup button
is not pressed, the flowmeter will enter the Run Mode and attempt to start flow
measurement. If the transducers are not installed on the pipe, a fault will occur. The
location of the Setup button is as follows:

The flowmeter indicates that it is in the Startup State as follows:

Model S1: a push-button switch on the
controller motherboard.

Model S2: as for Model S1.

Model S3: as for Model S2, plus a SETUP
soft button appears on the display.

Model S1: the Fault (red) LED is OFF and
all yellow LEDs are at first ON and then
turn OFF one by one, starting at LED1, at
intervals of 1.5 seconds, so as to count down
the 7 second pause.

Model S2: as for Model S1, plus the display
screen indicates:

Startup ...
Tap Setup to enter Setup Mode
Hold Setup for Zero Calibration
Configuration set #
(Searching for SD Card)

Below this, a “progress bar” counts off the 7
second delay.

Model S3: as for Model S2, plus the SETUP
soft button is available.

Tap Setup to enter Setup
Hold Setup for Zero Calibration

Startup …

[££££¢¢¢]

Information Screen

Configuration Set #1

Blue-White Industries, Sonic-Pro
Firmware Version, A01.00.00

(Searching for SD Card)

SETUP

Tap Setup to enter Setup
Hold Setup for Zero Calibration

Startup …

[££££¢¢¢]

Information Screen

Configuration Set #1

Blue-White Industries, Sonic-Pro
Firmware Version, A01.00.00

(Searching for SD Card)

MODEL S1

MODEL S2

MODEL S3

4.3
Startup
State

Advertising