0 indexes, Proseries, Sonic-pro – Blue-White Sonic-Pro Hybrid Ultrasonic Flowmeters User Manual

Page 66: 1 model number system, Page 66

Advertising
background image

Page 66

Sonic-Pro

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

TM

10.1
Model Number System

10.0 Indexes

Sonic-Pro Part Number Matrix

Signal Processing Unit (SPU) and Display Options

1

Model S1 - Factory configured - without display - no configuration menu access

S1

Model S2 -

- no configuration menu access

1

Factory configured - with display

S2

Model S3 - Factory configured - with display and with user configurable menu access

S3

2

Smart Communications and Control Options

Communications Includes Ethernet, USB, RS-232, RS-485 connections and user configuration and monitoring PC software.

A

Process Control Includes three 10 amp, Form C relays. Note: requires S3 configurable display or the communications option “A” above.

B

Both communications and Process Control options.

C

Power Supply Cord

Transducer Model

2” to 100” Pipe Size Range - Metal Housing Clamp-on Transducer - non-removable liquid tight cable gland connector only

A

2” to 100” Pipe Size Range - Plastic Housing Clamp-on Transducer - without T-Track mounting fixture

D

2” to 100” Pipe Size Range - Plastic Housing Clamp-on Transducer - single, V-mount T-Track (½”- 4” pipes sizes only)

E

3

Display Volume Units

L

G

U.S. Gallons
Liters

A

F

Cubic Feet
Acre Feet

I

M

Cubic Meters
Imperial Gallons

P

B

U.S. Barrels Liquid (31.5 Gal)
U.S. Barrels Oil (42.0 Gal)

K

O

Ounces
Milliliters

Display Time Units

M

Minutes

H

Hours

D

Days

4

Fluid

AD

AE

AA Alcohol (Ethyl alcohol; Ethanol)

Ethylene Glycol / water (50%)

Gasoline

AI

AJ

Milk

Oil (diesel)

AL

AN

AP

Water (distilled; waste)

Water (sea; brine)

Wine

Display Language (S4 models available in English only)

E

English

S

Spanish

G

German

F

French

S3

C

1

F

G

M

AL

E

Sample Sonic-Pro Part Number

Australia/New Zealand 250V with AS 3112 plug

8

None

X

B

2” to 100” Pipe Size Range - Plastic Housing Clamp-on Transducer - dual, Z-mount T-Track (½”- 4” pipes sizes only)

F

½” to 2” Pipe Size Range - Plastic Housing Clamp-on Transducer - without T-Track mounting fixture

I

½” to 2” Pipe Size Range - Plastic Housing Clamp-on Transducer - single, V-mount T-Track (½”- 4” pipes sizes only)

J

½” to 2” Pipe Size Range - Plastic Housing Clamp-on Transducer - dual, Z-mount T-Track (½”- 4” pipes sizes only)

K

No Transducers

X

Transducer Cable Length and Connection Type

10 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Metal Transducers only

1

25 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Metal Transducers only

2

50 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Metal Transducers only

3

100 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Metal Transducers only

4

E
F
G
H

Transducer Cable Length and Connection Type

Power cord without attachment plug

X

3

U.S. 250V with NEMA 6/15 plug

European 250V with CEE 7/VII plug

2

U.S. 125V with NEMA 5/15 plug

1

Ships without power cord or AC/DC transformer

0

A
B
C
D

10 ft cable length - with removable liquid-tight cable plug and socket - field replaceable - Plastic Transducers only
25 ft cable length - with removable liquid-tight cable plug and socket - field replaceable - Plastic Transducers only
50 ft cable length - with removable liquid-tight cable plug and socket - field replaceable - Plastic Transducers only
100 ft cable length - with removable liquid-tight cable plug and socket - field replaceable - Plastic Transducers only
10 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Plastic Transducers only
25 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Plastic Transducers only
50 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Plastic Transducers only
100 ft cable length - non-removable liquid-tight cable gland - not field replaceable - Plastic Transducers only

2” to 100” Pipe Size Range - Plastic Housing Clamp-on Transducer - single, V-mount T-Track (2”- 24” pipes sizes only)

G

2” to 100” Pipe Size Range - Plastic Housing Clamp-on Transducer - dual, Z-mount T-Track (2”- 24” pipes sizes only)

H

4

Nominal Pipe Size

IPS Pipe Size

2”
2-1/2”
3”

Metric Pipe Size

020
025
030

6”
8”
10”
12”

060
080
100
120

4”
5”

040
050

14”
16”

141
161

18”
20”
22”
24”

181
201
220
240

30”
32”
34”
36”

300
320
340
360

26”
28”

260
281

42”
48”

420
480

40mm

50mm
63mm
75mm

041

051
063
075

125
140
160
180

90mm
110mm

090
110

200
225

250
280
315
355

500
560
630
710

400
450

800
101

125mm
140mm
160mm
180mm
200mm
225mm

250mm
280mm
315mm
355mm
400mm
450mm

500mm
560mm
630mm
710mm
800mm
1000mm

4

Pipe Pressure Rating

SA
SB
SC
SD
SE
SF

SK

Sch 5 (ASTM D 1785)
Sch 10 (ASTM D 1785)
Sch 20 (ASTM D 1785)
Sch 30 (ASTM D 1785)
Sch 40 (ASTM D 1785)
Sch 60 (ASTM D 1785)
Sch 80 (ASTM D 1785)

SH
SI

Sch 120 (ASTM D 1785)
Sch 140 (ASTM D 1785)

SJ

Sch 160 (ASTM D 1785)

DA
DB
DC
DD

DE
DF

SDR 41 (ASTM D 2241)
SDR 26 (ASTM D 2241)
SDR 21 (ASTM D 2241)
SDR 19 (ASTM D 2241)

SDR 17 (ASTM D 2241)
SDR 15.5 (ASTM D 2241)
SDR 13.5 (ASTM D 2241)

DG
DH
DI

SDR 11 (ASTM D 2241)
SDR 9 (ASTM D 2241)

CA
CB
CC
CD
CE
CF

Class 50 (ANSI C151)

CG

Class 51 (ANSI C151)
Class 52 (ANSI C151)
Class 53 (ANSI C151)
Class 54 (ANSI C151)
Class 55 (ANSI C151)
Class 56 (ANSI C151)

TA
TB
TC
TK
TL
TM

Sanitary Tubing 0.065” wall
Sanitary Tubing 0.083” wall
Sanitary Tubing 0.109” wall
Type K copper (ASTM B 88)
Type L copper (ASTM B 88)
Type M copper (ASTM B 88)

PA
PB
PC
PD
PE
BB

PN 4 metric (DIN 8062)
PN 6 metric (DIN 8062)
PN 10 metric (DIN 8062)
PN 16 metric (DIN 8062)
PN 20 metric (DIN 8062)
Class B British (BS 3506)

BC Class C British (BS 3506)
BD Class D British (BS 3506)
BE Class E British (BS 3506)
B7

Class 7 British (BS 3506)

4

Pipe Material

B
C
D

E

A

Brass (naval)
Copper
FRP (fiberglass reinforced plastic)
Iron (cast)

Iron (ductile)

G

I

J

Polyethylene (HDPE)
Polypropylene
PVC / CPVC

L
M
N

O

K

PVDF
Stainless Steel 304

Stainless Steel 316

Steel (1% Carbon, hardened)

Stainless Steel 304L

P

Steel (Carbon)

DL

SDR 18 (ASTM D 2241)

DP
DN
DM

DR14 (AWWA C900 PVC PIPE)
DR18 (AWWA C900 PVC PIPE)
DR25 (AWWA C900 PVC PIPE)

20mm (plastic pipe only)
25mm
32mm

021
026
032

1/2” (plastic pipe only)
3/4”
1”

005
007
010
012
1-1/4”

015 1-1/2”

P

SD

120

Z

No Cable - (use for transducers with field replaceable cable plug shipped without cable)

Advertising