Proseries, Sonic-pro, 10 transducer mounting clamps – Blue-White Sonic-Pro Hybrid Ultrasonic Flowmeters User Manual

Page 47

Advertising
background image

Page 47

Sonic-Pro

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

TM

6.10
Transducer
Mounting
Clamps

The meter is provided with five pipe clamps, four to be used for transducer mounting and
a fifth for mounting the SPU.

The clamps can be chained together if required for larger pipe diameters.

Additional clamps can be purchased from the factory.

Carefully place the first transducer onto the pipe

. Be sure the

transducer is placed straight and parallel to the pipe centerline.

Secure the first transducer to the pipe using the enclosed pipe clamps. The arrows on the
front and rear of the transducers must point toward the pipe centerline mark.

Locate the second transducer separation mark (B).

Be sure

that both transducers are facing each other and parallel to the pipe centerline.

Check that the separation distance is correct. Tighten the clamps equally.

A single clamp can be used on a pipe diameter of up to 10

inches.

so that the front arrow on the

transducer is located exactly over the first separation distance mark (A)

Carefully place the second transducer

onto the pipe so that the front arrow on the transducer is located exactly over the mark
(B). Be sure the transducer is placed straight and parallel to the pipe centerline.

A

B

Separation

Distance

A

B

BLUE

GASKET

MOUNTING CLAMPS

A

B

CENTERLINE

CENTERLINE

FRONT VIEW

ARROW ON CENTERLINE

REAR VIEW

ARROW ON CENTERLINE

CENTERLINE

CENTERLINE

Advertising