Local control panel & indicators, Local control and indicators – Ampro Corporation DLP 5200 User Manual

Page 16

Advertising
background image

14

5200 User’s Manual

Local Control and Indicators

Controls

Located at the rear of the projector is the local control panel. The controls allow the user to
perform the following functions.



PWR (POWER): Allows the user to power the projector on and off.



MENU: Enters the On-Screen-Display Mode.



SEL (SELECT): Use the SEL key to select the highlighted function.



STBY (STANDBY): Use to toggle the projected image on or off.



ARROW KEYS: Use to scroll through menu items. Once an item has been selected, use
the arrow keys to adjust the selected function.

Indicators

External L.E.D. Indicators: Located at the rear of the projector (just above the local control
panel) are five L.E.D.s These L.E.D.s will indicate the status of the projector through the boot
sequence and operation.



LAMP: This L.E.D. indicates the lamp power supply is on and the lamp should be lit.



Green-normally “ON”.



ENGINE: Indicates the display engine is turned “on” and operational.



Green-normally “ON”.



LVPS: Indicates main AC is applied, switch is “on” and the P.C. power supply is
operational.



Green-normally “ON”



HDD: Hard-disk drive. Lights up or flashes when the drive is in use or active.



Red-normally “FLASHES”



READY: Initially this indicator blinks, indicating the PC. is in the boot cycle. When the
P.C. has completed the boot cycle, the L.E.D. will become steady and the projector is
ready for the power-on command from the remote control or keyboard.



Amber- Initially “BLINKS”, then “STEADY”.

Advertising