Mounting the csg, Instructions for wall mounting – AMX SIP Communications Gateway CSG-500 User Manual

Page 18

Advertising
background image

Installation

10

CSG SIP Communications Gateway Operation/Reference Guide

Mounting the CSG

FIG. 4 illustrates the proper mounting installation options for wall mounting the unit:

Instructions for Wall Mounting

1.

Select the area to mount the CSG unit (refer to FIG. 4). The unit should be mounted at or below eye
level to properly view the LEDs.

2.

Line up one of the surface mounting brackets with the two holes on one side of the CSG. Install two
#4-40 X .250 PPH screws into the holes in the bracket to secure the bracket to the CSG.

3.

Repeat step 2 to attach the second bracket to the other side of the unit.

4.

Affix one screw to the wall. Leave approximately 1/4-inch of the screw protruding from the wall to
allow the head of the screw to slide into the settings on the mounting bracket, mounting the unit to
the wall.

5.

Repeat step 4 to attach the second bracket to the wall.

Instructions for Wall Mounting Using DIN Rail Mounting Brackets

The AC-DIN-CS3 DIN Rail Mounting Brackets (FG532-06) allow you to install the CSG on a standard
DIN rail (or “top-hat” rail). The DIN Rail Mounting Bracket comes in a kit that includes everything you
need to mount a single device on a standard (35 MM. wide) metal DIN rail. Follow these steps to mount
the CSG using the DIN rail mounting brackets:

1.

Use the four supplied flat-head screws to secure the DIN mounting clips to the bracket.

2.

Use the two supplied pan-head screws to secure the bracket/mounting clip assembly to the CSG.
Use the mounting holes on either side panel of the enclosure to mount the bracket/mounting clip
assembly.

3.

Snap the bracket/clamp onto the DIN rail.

FIG. 4

Acceptable Mounting Orientation options (wall mounting)

LEDs pointing UP

DO NOT point the LEDs DOWN

LEDs pointing SIDEWAYS

Advertising