Configuring voip, Installing the netlinx module – AMX SIP Communications Gateway CSG-500 User Manual

Page 82

Advertising
background image

Device Configuration

74

CSG SIP Communications Gateway Operation/Reference Guide

Configuring VoIP

1.

On the Configuration page, select the SIP Settings tab.

2.

In the Username field, enter the user name used for authentication to the proxy server.

3.

In the Password field, enter the password for the user name.

4.

In the Server Address field, enter the IP address or DNS name of the proxy server you want to use to
register.

5.

In the Server Port field, enter the port of the proxy server.

6.

In the STUN Address field, enter the IP address or DNS name of the STUN server. This step is
optional.

7.

In the Local Domain field, enter the realm used for authentication. This step is optional.

8.

Click the Enable option button to activate the SIP settings.

9.

Click Accept.

Installing the NetLinx Module

Each panel has an available module which may be helpful with getting the panel to work with the CSG.
Download the module for the intercom panel from the Tech Center at www.amx.com. Unzip the file, and
include it in your NetLinx project file. For information on using the NetLinx Module, consult the
Communications Module User Guide available at www.amx.com.

You can load a Duet module to enable the entry communicator to utilize SIP to
contact other units and touch panels. The Duet module translates between the
standard interface and the device protocol. It parses the buffer for responses from the
device, sends strings to control the device, and receives commands from the UI
module or telnet sessions. Refer to the documentation supplied with the Duet Module
and the Communications Module User Guide (available at www.amx.com) for more
details.