15

Hydraulic system data

Values

Total hydraulic system oil capacity

26.7 USgal (101 litres)

Maximum drive system pressure

5,076 psi (350 Bar)

Cooling fan system maximum pressure

2,611 psi (180 Bar)

Maximum accessory system pressure

2,466 psi (170 Bar)

Maximum turbine system pressure

1,595 psi (110 Bar)

Maximum steering system pressure

1,740 psi (120 Bar)

Hydraulic system oil type

AGIP ARNICA 46 (*)(**)

Dust control system pump oil type

Agip Sigma Super TFE 10W40 (***)

Electrical system data

Values

System voltage

12 V

Starting battery

12 V – 100 Ah

If the machine is to be used at ambient temperatures below +10 °C, the oil should be replaced with equivalent oil having a

(*)

viscosity of 32 cSt. For temperatures below 0 °C, use oil with lower viscosity.
See the hydraulic system oil technical data and reference data tables below.

(**)

For further details, see the engine oil tables.

(***)

AGIP ARNICA 46/32 SPECIFICATIONS

Approvals and specifi cations

46

32

ISO-L-HV

Viscosity at 100 °C

mm

2

/s

45

32

ISO 11158

Viscosity at 40 °C

mm

2

/s

7.97

6.40

AFNOR NF E 48603 HV

Viscosity index

/

150

157

AISE 127

Flash point COC

°C

215

202

ATOS Tab. P 002-0/I

Pour point

°C

-36

-36

BS 4231 HSE

Density at 15 °C

kg/l

0.87

0.865

CETOP RP 91 H HV

COMMERCIAL HYDRAULICS

Danieli Standard 0.000.001 (AGIP ARNICA
22, 46, 68)

EATON VICKERS I-286-S3

EATON VICKERS M-2950

DIN 51524 t.3 HVLP

LAMB LANDIS-CINCINNATI P68, P69, P70

LINDE

PARKER HANNIFIN (DENISON) HF-0

REXROTH RE 90220-1/11.02

SAUER-DANFOSS 520L0463

Climate control system data

Values

Gas type

Reclin 134A

Gas quantity

0.8 kg

Camera kit description (optional) (*)

Values

Make

Continental VDO -

Type

LCD 5" colour monitor
Infrared colour camera

For other data/values of the optional equipment, see the relevant Manuals.

(*)