47

Problem

Possible cause

Remedy

SUCTION INLET AND SKIRT

The suction inlet does not lower

The lowering control has not been used prop-
erly

Hold the control pressed longer

The safety chain is locked

Release

There is an open in the lowering push-button

Replace

The power supply fuse is open

Replace

The distributor solenoid valve is not powered

Check the electrical system

There is no pressure at the hydraulic system

Check the pump pressure

The cylinder calibration dowels are clogged

Disassemble and clean

The skirt does not open/close

There is an open in the opening/closing
switches

Replace

The power supply fuse is open

Replace

The distributor solenoid valves are not powered Check the electrical system

There is no pressure at the hydraulic system

Check the pump pressure

The cylinder calibration dowel is clogged

Disassemble and clean

The skirt is damaged or jammed

Repair

HOPPER AND RELEVANT DOOR

The hopper does not lift/dump

The working mode is not activated

Activate the working mode switch

The hopper sensors are out of position or dam-
aged

Adjust or replace

The hopper is not at a safe position to be
dumped

Lift the hopper more

There is an open in the lifting/dumping switches Replace

The power supply fuse is open

Replace

The distributor solenoid valves are not powered Check the electrical system

The solenoid valves are stuck

Replace

There is no pressure at the hydraulic system

Check the pump pressure

The hopper does not return to horizontal posi-
tion/lower

The support rod is not engaged

Lift and engage

The hopper has not returned to horizontal
position

Fully retract before lowering

The hopper sensors are out of position or dam-
aged

Adjust or replace

There is an open in the lifting/dumping switches Replace

The power supply fuse is open

Replace

The distributor solenoid valves are not powered Check the electrical system

The solenoid valves are stuck

Replace

There is no pressure at the hydraulic system

Check the pump pressure

The hopper door does not open/close

The hopper is not at a safe position to be
dumped

Lift the hopper more

The locking cylinder calibration dowels are
clogged

Disassemble and clean

The hooks are locked

Disassemble and clean

The door has not fully lowered before activation
of the fan

Dump and retract the hopper

Advertising