49

Problem

Possible cause

Remedy

DRIVE SYSTEM

The machine drive system is disabled

The driver’s seat microswitch is not activated or
it is damaged

Repair/replace

The pedal brake is pressed or stuck

Release the pedal

The power supply fuse is open

Replace

The drive pedal is faulty

Replace

The gear selector is faulty

Replace

The drive system pump solenoid valves are not
powered

Check the electrical system

The drive system pump by-pass screw is
loosen

Tighten

The drive system pump is broken

Replace

The drive system motors are broken

Replace

The machine moves even if the drive pedal is
released

The drive system pump is not properly reset

Adjust

The machine drive power is reduced

The hopper is lifted

Fully lower the hopper and return it to horizon-
tal position

The drive pedal is faulty

Replace

The drive system pump is broken

Replace

The drive system motors are worn

Replace

CAB HEATING

There is no hot air

The valve or the hot water feed hoses are
broken

Replace

There are water leaks from the heater

Replace

The switch is off

Turn on

The main fuse is open

Replace

CAB CLIMATE CONTROL SYSTEM

There is no fresh air

The compressor does not turn because the
drive belt is loosen/broken

Adjust the tension/replace the belt

The thermostat is not turned on

Turn on

There are gas leaks from the system

Repair the leak and integrate the gas

The expansion valve is faulty

Replace

The switch is off

Turn on

The main fuse is open

Replace

There is an open in the gas pressure switch

Replace