Installation

31

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

How to Change Injector (Orifice) Size

1. Disconnect electrical power from tumbler. Close

gas shut-off valve to tumbler. Refer to Figure 6.

2. For Johnson GM7000 gas valve:

Remove burner orifice(s) from the spud holder.
Refer to Figure 7.

3. Install the new, correct injector(s) (orifices).

Refer to Figure 8. Torque each to 9 – 10 Nm.

4. Commission tumbler for use.

NOTE: Blank injectors (orifices) are available as
Part No. M400995.

How to Adjust Gas Valve Governor/Regulator

1. Check gas injector (manifold) pressure as

follows. Refer to Figure 7.

2. Loosen screw plug inside pressure tap located on

underside of valve.

3. Connect a “U”-tube manometer (or similar

pressure gauge) to the tap.

4. Start tumbler and note pressure once flame is

burning. Remove regulator cap and adjust
regulator screw until the injector pressure per
applicable table is achieved. Replace regulator
cap and close needle valve (pressure tap).

5. Commission tumbler for use.

Figure 8

TMB2015N

1

Size Stamped on Orifice

1

BURNER INJECTOR

(ORIFICE)

Advertising