Alliance Laundry Systems 70269701R4 User Manual

Page 57

Advertising
background image

Electrical Requirements

55

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For 21 kW Models:
30 Pound Electric
T30 Electric not available in single phase.

Table 12

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

[AWG (mm

2

)]

208V/60Hz/1ph

L1, L2, Neutral,

and ground

108

150

2

1/0 (53.5)

240V/60Hz/1ph

L1, L2, Neutral,

and ground

94

125

2

1 (42.4)

200V/60Hz/1ph

L1, Neutral,

and ground

108

150

1

1/0 (53.5)

200V/50Hz/1ph

L1, Neutral,

and ground

105

150

1

1/0 (53.5)

230-240V/50Hz/1ph

L1, Neutral,

and ground

95

125

1

1 (42.4)

200-208V/60Hz/3ph**

L1, L2, L3,

and ground

62***

80*

3

4 (21.2)

200V/50Hz/3ph**

L1, L2, L3,

and ground

60

80*

3

4 (21.2)

230-240V/50Hz/3ph**

L1, L2, L3,

and ground

55***

70*

3

4 (21.2)

240V/60Hz/3ph**

L1, L2, L3,

and ground

54***

70*

3

4 (21.2)

380V/50Hz/3ph**

L1, L2, L3,

and ground

33***

45*

3

8 (8.37)

380V/50Hz/3ph

(035E Model)

L1, L2, L3,

and ground

34

45*

3

8 (8.37)

400-415V/50Hz/3ph**

L1, L2, L3,

and ground

31***

40*

3

8 (8.37)

460-480V/60Hz/3ph**

L1, L2, L3,

and ground

27***

35*

3

8 (8.37)

*

3 Phase machines should not have fuses, breakers only.

** These serial plate voltages are only options available on the 30 Pound Single and Stacked electric models. Current (Amp) is for one

pocket only.

*** Per heater on T30 electric models, each has two heaters.