Alliance Laundry Systems 70269701R4 User Manual

Page 58

Advertising
background image

Electrical Requirements

70269701

56

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For 24 kW Models:
35 Pound Electric

Table 13

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or Breaker

Rating (Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

[AWG (mm

2

)]

208V/60Hz/1ph

L1, L2, Neutral,

and ground

122

175

2

2/0 (67.5)

240V/60Hz/1ph

L1, L2, Neutral,

and ground

107

150

2

1/0 (53.5)

200V/60Hz/1ph

L1, Neutral,

and ground

122

175

1

2/0 (67.5)

200V/50Hz/1ph

L1, Neutral,

and ground

119

150

1

1/0 (53.5)

230-240V/50Hz/

1ph

L1, Neutral,

and ground

108

150

1

1/0 (53.5)

200-208V/60Hz/

3ph

L1, L2, L3,

and ground

71

90*

3

3 (26.7)

200V/50Hz/3ph

L1, L2, L3,

and ground

65

90*

3

3 (26.7)

230-240V/50Hz/

3ph

L1, L2, L3,

and ground

62

80*

3

4 (21.2)

240V/60Hz/3ph

L1, L2, L3,

and ground

62

80*

3

4 (21.2)

380V/50Hz/3ph

L1, L2, L3,

and ground

38

50*

3

6 (13.3)

400-415V/50Hz/

3ph

L1, L2, L3,

and ground

35

45*

3

8 (8.37)

460-480V/60Hz/

3ph

L1, L2, L3,

and ground

31

40*

3

8 (8.37)

*

3 Phase machines should not have fuses, breakers only.